{"id":70193,"date":"2018-06-19T11:26:52","date_gmt":"2018-06-19T15:26:52","guid":{"rendered":"https:\/\/www.exittechnlive.wpenginepowered.com\/?p=70193"},"modified":"2026-02-16T15:32:34","modified_gmt":"2026-02-16T15:32:34","slug":"energieffektivitetsguide-for-datacenter","status":"publish","type":"post","link":"https:\/\/exittechnologies.com\/sv\/blogg\/datacenter\/energieffektivitetsguide-for-datacenter\/","title":{"rendered":"Guide f\u00f6r b\u00e4sta praxis f\u00f6r energieffektivisering av datacenter (f\u00f6rb\u00e4ttra din PUE)"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid: <\/span> <span class=\"rt-time\"> 10<\/span> <span class=\"rt-label rt-postfix\">Protokoll<\/span><\/span>\n<p>Detta <span id=\"urn:enhancement-c8197d8\" class=\"textannotation disambiguated wl-thing wl-no-link\">Datacenter<\/span> Energy Efficiency Best Practices Guide har tagits fram f\u00f6r att hj\u00e4lpa datacenter att minska sin prim\u00e4ra driftskostnad: <span id=\"urn:enhancement-d5c3cf99\" class=\"textannotation disambiguated wl-thing wl-no-link\">energif\u00f6rbrukning<\/span>. <\/p>\n\n\n\n<p>I takt med att dataf\u00f6rbrukningen forts\u00e4tter att \u00f6ka exponentiellt m\u00e5ste datacentren maximera sin energieffektivitet f\u00f6r att undvika att drabbas av h\u00f6ga elkostnader. <\/p>\n\n\n\n<p>I den h\u00e4r artikeln beskrivs de b\u00e4sta metoder som datacenter kan anv\u00e4nda f\u00f6r att f\u00f6rb\u00e4ttra sin energieffektivitet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">F\u00f6rst och fr\u00e4mst: M\u00e4t f\u00f6r att f\u00f6rb\u00e4ttra<\/h2>\n\n\n\n<p>Som Peter Drucker s\u00e5 ofta citeras f\u00f6r att ha sagt:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>Om du inte kan m\u00e4ta det kan du inte heller f\u00f6rb\u00e4ttra det.<\/p>\n<\/blockquote>\n\n\n\n<p>Innan du \u00f6verv\u00e4ger n\u00e5gon av de andra strategierna i den h\u00e4r artikeln \u00e4r det viktigt att du redan har ett m\u00e4tsystem p\u00e5 plats.<\/p>\n\n\n\n<p>Google \u00e4r s\u00e5 m\u00e5na om att m\u00e4ta exakt att de tar stickprov p\u00e5 PUE (Power Usage Effectiveness) minst en g\u00e5ng per sekund. <\/p>\n\n\n\n<p>Genom att m\u00e4ta \u00f6ver hela \u00e5ret tar du h\u00e4nsyn till s\u00e4songsvariationer i v\u00e4dret och deras effekter p\u00e5 datacentrets kylf\u00f6rbrukning. <\/p>\n\n\n\n<p>Kompetenscentret f\u00f6r energieffektivitet i datacenter har en&nbsp;<a rel=\"noopener noreferrer\" href=\"https:\/\/datacenters.lbl.gov\/resources\/data-center-metering-and-resource-guide\" target=\"_blank\">anv\u00e4ndbar guide<\/a> om m\u00e4tning av energieffektivitet i datacenter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kylning<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" width=\"750\" height=\"400\" src=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-cooling-solutions-to-improve-data-center-energy-efficiency.jpg\" alt=\"kylning av datacenter-b\u00e4sta metoder f\u00f6r energieffektivisering\" class=\"wp-image-70200\" srcset=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-cooling-solutions-to-improve-data-center-energy-efficiency.jpg 750w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-cooling-solutions-to-improve-data-center-energy-efficiency-300x160.jpg 300w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<p>Kylutrustningen st\u00e5r f\u00f6r en stor del av energif\u00f6rbrukningen i ett datacenter. F\u00f6r datacenter <span id=\"urn:enhancement-94ececc\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> specialister \u00e4r det viktigt att hitta nya s\u00e4tt att f\u00f6rb\u00e4ttra str\u00f6mf\u00f6rbrukningseffektiviteten (PUE), och d\u00e4rf\u00f6r \u00e4r kylning av st\u00f6rsta intresse.<\/p>\n\n\n\n<p>Av kylutrustningen \u00e4r det chillers och CRAC som f\u00f6rbrukar mest energi, s\u00e5 det \u00e4r avg\u00f6rande f\u00f6r effektiviteten att minimera deras arbetsbelastning.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">B\u00e4sta praxis f\u00f6r standardiserad energieffektivisering f\u00f6r enkla vinster<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>F\u00f6r de flesta genomsnittliga datacenter \u00e4r det popul\u00e4rt att anv\u00e4nda varmg\u00e5ngs-\/kallg\u00e5ngsavgr\u00e4nsning f\u00f6r att f\u00f6rb\u00e4ttra luftkylningseffektiviteten och det \u00e4r enkelt att eftermontera i befintliga datacenter. Det hj\u00e4lper till att isolera och eliminera v\u00e4rmekaos och hot spots.\n<ul class=\"wp-block-list\">\n<li>F\u00f6r att b\u00e4ttre kunna separera g\u00e5ngarna \u00e4r det vanligt att man t\u00e4pper till h\u00e5l i rackplatserna med \"blindpl\u00e5tar\" f\u00f6r att f\u00f6rhindra v\u00e4rmel\u00e4ckage. <\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Under de senaste \u00e5ren har rack med anslutna v\u00e4tskekylningsenheter kunnat avlasta luftkylningen till en br\u00e5kdel av energikostnaden, utan att datacentret beh\u00f6ver byggas om<\/li>\n\n\n\n<li>F\u00f6r att f\u00f6rst\u00e4rka traditionell luftkylning med inneslutning finns det ekonomiserare som kan anv\u00e4ndas f\u00f6r att utnyttja \"gratis\" kylning n\u00e4r milj\u00f6n till\u00e5ter det, vilket minskar energif\u00f6rbrukningen ytterligare. T\u00e4nk bara p\u00e5 att utomhusluften kan inneh\u00e5lla f\u00f6roreningar och fukt och filtrera eller avst\u00e5 fr\u00e5n att filtrera.<\/li>\n\n\n\n<li>En annan vanlig metod \u00e4r att helt enkelt h\u00f6ja den omgivande temperaturen i datacentret. Den mesta utrustningen fungerar utm\u00e4rkt i en kall g\u00e5ng med en temperatur p\u00e5 \u00f6ver 26\u00b0C, och genom att h\u00f6ja omgivningstemperaturen kan kylbehovet minskas avsev\u00e4rt<\/li>\n\n\n\n<li>Computational Fluid Dynamics kan anv\u00e4ndas f\u00f6r att skapa en termisk modell av ditt datacenter och optimera kylning och luftfl\u00f6de utan att n\u00f6dv\u00e4ndigtvis beh\u00f6va omorganisera datacentret. CFT kan anv\u00e4ndas f\u00f6r att testa hur systemet reagerar p\u00e5 olika f\u00f6rh\u00e5llanden och hj\u00e4lpa till att identifiera problemomr\u00e5den som kan f\u00f6rb\u00e4ttras.\n<ul class=\"wp-block-list\">\n<li>CFD kan ocks\u00e5 anv\u00e4ndas med stor effekt vid utformningen av ett datacenter. T\u00e4nk p\u00e5 att modellering \u00e4r en otroligt komplex process som interpolerar stora m\u00e4ngder data, och verktygen har begr\u00e4nsningar i skrivande stund 2018. De \u00e4r egentligen inte avsedda f\u00f6r realtids\u00f6vervakning, och vissa felaktigheter \u00e4r oundvikliga med tyngre ber\u00e4kningar. <\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p>\u00c4ven om de ovan n\u00e4mnda bitarna \u00e4r allm\u00e4nt vedertagna som b\u00e4sta praxis, har m\u00e5nga datacenter inte uppdaterat sina <span id=\"urn:enhancement-b7c89298\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> nyligen eller f\u00f6rv\u00e4rvat vinner den enkla effektiviteten. H\u00e4r \u00e4r ett diagram fr\u00e5n submer.com f\u00f6r att illustrera konceptet med kall g\u00e5ng\/varm g\u00e5ng:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" width=\"639\" height=\"818\" src=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-energy-efficiency-guide-hot-cold-aisle-containment.png\" alt=\"hot-aisle-cold-aisle-b\u00e4sta praxis f\u00f6r energieffektivisering av datacenter\" class=\"wp-image-70194\" srcset=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-energy-efficiency-guide-hot-cold-aisle-containment.png 639w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/data-center-energy-efficiency-guide-hot-cold-aisle-containment-234x300.png 234w\" sizes=\"(max-width: 639px) 100vw, 639px\" \/><\/figure>\n\n\n\n<p>F\u00f6rutom att optimera befintliga kylningsparadigm finns det flera andra kylningsmetoder som kan ge en betydande effektivitets\u00f6kning ut\u00f6ver standardmetoderna.<\/p>\n\n\n\n<p>En av dessa metoder \u00e4r direkt evaporativ kylning.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Direkt evaporativ kylning<\/h2>\n\n\n\n<p>Direkt evaporativ kylning (DEC) anv\u00e4nder dimma f\u00f6r att skapa ett substrat f\u00f6r avdunstning. Om du n\u00e5gonsin har sett fl\u00e4ktarna som bl\u00e5ser dimma i Las Vegas f\u00f6r att kyla ner semesterfirare vid poolen, har du sett den h\u00e4r mekanismen i aktion.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" width=\"600\" height=\"362\" src=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/Direct-evaporative-cooling-energy-efficiency-guide-for-data-centers.png\" alt=\"B\u00e4sta praxis f\u00f6r energieffektivisering av datacenter med direkt evaporativ kylning\" class=\"wp-image-70195\" srcset=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/Direct-evaporative-cooling-energy-efficiency-guide-for-data-centers.png 600w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/Direct-evaporative-cooling-energy-efficiency-guide-for-data-centers-300x181.png 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p>H\u00e4r \u00e4r ett diagram \u00f6ver hur direkt evaporativ kylning fungerar fr\u00e5n dchuddle.com:<br><\/p>\n\n\n\n<p>Enligt Anne Wood, chef p\u00e5 Phoenix MFG, inc, \u00e4r det inte ovanligt med en effektivitets\u00f6kning p\u00e5 50% fr\u00e5n DEC. Det finns dock n\u00e5gra saker att t\u00e4nka p\u00e5:<\/p>\n\n\n\n<p>Sj\u00e4lvklart, f\u00f6r att anv\u00e4nda <span id=\"urn:enhancement-b35b1770\" class=\"textannotation disambiguated wl-thing\">vatten f\u00f6r kylning<\/span>m\u00e5ste datacentret ha tillg\u00e5ng till en rimlig m\u00e4ngd vatten.<\/p>\n\n\n\n<p>Direkt evaporativ kylning kr\u00e4ver ocks\u00e5 ett system f\u00f6r att rena vattnet, lagra reservvatten, pumpa dimman och regulatorer f\u00f6r att kontrollera vattenfl\u00f6de och tryck.<\/p>\n\n\n\n<p>Dessutom tillf\u00f6r direkt evaporativ kylning fukt till datacentret, vilket g\u00f6r direkt evaporativ kylning mer anv\u00e4ndbar i vissa anv\u00e4ndningsfall \u00e4n i andra. <\/p>\n\n\n\n<p>I synnerhet datacenter i torrare klimat med tillg\u00e5ng till vatten skulle sannolikt dra nytta av en DEC-l\u00f6sning. <\/p>\n\n\n\n<p>Innan du \u00f6verv\u00e4ger en s\u00e5dan kan fuktsensorer och prediktiv modellering hj\u00e4lpa till att f\u00f6ruts\u00e4ga om DEC kommer att pressa upp rummets luftfuktighetsniv\u00e5er \u00f6ver standardgr\u00e4nserna f\u00f6r 60%.<\/p>\n\n\n\n<p>Indirekt evaporativ kylning \u00e4r en n\u00e5got mindre vanlig, men lika g\u00e5ngbar l\u00f6sning som bygger p\u00e5 samma koncept.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Indirekt evaporativ kylning<\/h2>\n\n\n\n<p>Den tar i princip varm luft fr\u00e5n utsidan av datacentret och f\u00f6r den genom en <span id=\"urn:enhancement-a48ed165\" class=\"textannotation disambiguated wl-thing\">v\u00e4rmev\u00e4xlare<\/span>. Den <span id=\"urn:enhancement-4505ca6a\" class=\"textannotation disambiguated wl-thing\">v\u00e4rmev\u00e4xlare<\/span> underl\u00e4ttar avdunstning, vilket kyler luften n\u00e4r den skickas in i datacentret. <\/p>\n\n\n\n<p>Samtidigt f\u00f6rsvinner fukt och v\u00e4rme tillbaka ut fr\u00e5n v\u00e4xlaren. Nackdelen med detta \u00e4r att en <span id=\"urn:enhancement-fc9b06d2\" class=\"textannotation disambiguated wl-thing\">v\u00e4rmev\u00e4xlare<\/span> f\u00f6rlorar n\u00e5gra grader i kylning j\u00e4mf\u00f6rt med direkt evaporativ kylning. <\/p>\n\n\n\n<p>Indirekt evaporativ kylning kr\u00e4ver ocks\u00e5 tv\u00e5 fl\u00e4ktar ist\u00e4llet f\u00f6r en, precis som indirekt evaporativ kylning.<\/p>\n\n\n\n<p>F\u00f6rdelen med indirekt evaporativ kylning \u00e4r att den inte tillf\u00f6r n\u00e5gon luftfuktighet eller yttre element till datacentermilj\u00f6n, vilket kan vara ett problem eller inte.<\/p>\n\n\n\n<p><strong>F\u00f6r att sammanfatta:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Om partiklar eller luftfuktighet \u00e4r ett problem \u00e4r indirekt evaporativ kylning i allm\u00e4nhet l\u00e4mpligare<\/li>\n\n\n\n<li>Datacenter med tillg\u00e5ng till vatten och som inte bryr sig om v\u00e4der och vind f\u00e5r b\u00e4ttre effektivitet med direkt evaporativ kylning.<\/li>\n<\/ul>\n\n\n\n<p>Den mest innovativa av de senaste kylstrategierna \u00e4r dock immersionskylning.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kylning genom neds\u00e4nkning<\/h2>\n\n\n\n<p>Alibaba har \u00e5tagit sig att anv\u00e4nda neds\u00e4nkningskylning i sina datacenter och uppskattar att det kommer att spara utrymme med 75%, \u00f6ka effektt\u00e4theten och minska driftskostnaderna med 20%. <\/p>\n\n\n\n<p>N\u00e4r det g\u00e4ller b\u00e4sta praxis f\u00f6r energieffektivitet i datacenter kommer neds\u00e4nkningskylning mycket snart att vara en standard p\u00e5 listan.<\/p>\n\n\n\n<p>Alibabas kylteknik f\u00f6r neds\u00e4nkning i vatten <a href=\"https:\/\/www.datacenterdynamics.com\/pictures\/2000x2000fit\/5\/6\/6\/21566_immersion-cooling.JPG\" target=\"_blank\" rel=\"noopener noreferrer\">fr\u00e5n datacenterdynamics.com<\/a>:<\/p>\n\n\n\n<figure><img decoding=\"async\" class=\"aligncenter size-large wp-image-70202\" src=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology-1024x684.jpg\" alt=\"energieffektivitet i datacenter b\u00e4sta praxis omfattande lista\" width=\"512\" height=\"342\" srcset=\"https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology-1024x684.jpg 1024w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology-300x200.jpg 300w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology-768x513.jpg 768w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology-1536x1026.jpg 1536w, https:\/\/exittechnologies.com\/wp-content\/uploads\/2018\/06\/alibaba-immersion-cooling-technology.jpg 1920w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<p>Trots att det finns s\u00e5 stora m\u00f6jligheter att minska PUE i datacenter \u00e4r tanken p\u00e5 att doppa sig i v\u00e4tska obekv\u00e4m f\u00f6r m\u00e5nga IT-f\u00f6retag.<\/p>\n\n\n\n<p>I takt med att tekniken f\u00f6rb\u00e4ttras och fler tidiga anv\u00e4ndare dyker upp har det blivit uppenbart att immersionskylning inte bara \u00e4r genomf\u00f6rbart utan ocks\u00e5 absolut n\u00f6dv\u00e4ndigt om datacenter ska kunna h\u00e5lla j\u00e4mna steg med de \u00f6kande effektivitetsbehoven i moderna datacenter.<\/p>\n\n\n\n<p>I datacenter med h\u00f6g densitet kommer kylning genom neds\u00e4nkning sannolikt att vara avg\u00f6rande, men befintliga datacenter \u00e4r l\u00e5ngsammare med att inf\u00f6ra tekniken.<\/p>\n\n\n\n<p>N\u00e5gra av problemen med immersionskylning \u00e4r kostnader och r\u00f6righet, <span id=\"urn:enhancement-ba0dbf38\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> eftermontering, h\u00e5rddiskkompatibilitet, leverant\u00f6rskompatibilitet, vikt, s\u00e4kerhet, golvyta och resursf\u00f6rbrukning. <\/p>\n\n\n\n<p>Dessa problem \u00e4r visserligen giltiga i samband med omfattande eftermonteringsprojekt, men de utg\u00f6r inte l\u00e4ngre tillr\u00e4ckliga nackdelar f\u00f6r att f\u00f6rhindra ett brett inf\u00f6rande i framtida projekt.<\/p>\n\n\n\n<p>Vi tar en titt p\u00e5 var och en av dem p\u00e5 h\u00f6g niv\u00e5.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kostnader<\/h3>\n\n\n\n<p>Immersionskylning medf\u00f6rde kostnadsp\u00e5slag som uppv\u00e4gde m\u00e5nga av dess energieffektivitetsf\u00f6rdelar, s\u00e4rskilt vid eftermontering. Faktorer som \u00e4r ansvariga f\u00f6r dessa kostnadspremier inkluderar:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mess<\/h3>\n\n\n\n<p>Faktum \u00e4r att olja och andra dielektriska v\u00e4tskor kan \u00f6ka behovet av underh\u00e5llsarbete. Detta varierar beroende p\u00e5 vilken leverant\u00f6r av l\u00f6sningar som anv\u00e4nds.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Retrofit av infrastruktur<\/h3>\n\n\n\n<p>Tidigare fanns det inte n\u00e5gra mer universellt anv\u00e4ndbara l\u00f6sningar f\u00f6r neds\u00e4nkning. Detta kr\u00e4vde en total <span id=\"urn:enhancement-1985b2b1\" class=\"textannotation disambiguated wl-thing wl-no-link\">datacenter<\/span> eftermontering eller nybyggnadsprojekt f\u00f6r att tillgodose v\u00e4tskekylningstekniken. <\/p>\n\n\n\n<p>\u00c4ven om det fortfarande kan vara opraktiskt att byta ut \u00e4ldre datacenter mot ny kylteknik, \u00e4r immersionskylning en mer <a href=\"https:\/\/exittechnologies.com\/sv\/blogg\/datacenter\/juniper-vs-cisco\/\">effektivt val f\u00f6r de flesta nya datacenter<\/a> byggnader.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kompatibilitet med h\u00e5rddisk<\/h3>\n\n\n\n<p>Standardh\u00e5rddiskar kan inte s\u00e4nkas ned i v\u00e4tskekylsystem. <\/p>\n\n\n\n<p>Men f\u00f6rseglad snurrning <span id=\"urn:enhancement-d91b2e5a\" class=\"textannotation disambiguated wl-thing\">h\u00e5rddiskar<\/span> \u00e4r ett alternativ, och solid state-enheter tar upp mer golvyta i moderna datorer. <span id=\"urn:enhancement-fc8dd225\" class=\"textannotation disambiguated wl-thing wl-no-link\">datacenter<\/span>. <\/p>\n\n\n\n<p>Dessutom kan modifierade drivkaddyer anv\u00e4ndas f\u00f6r att h\u00e5lla drivningen ovanf\u00f6r oljeytan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Leverant\u00f6rskompatibilitet<\/h3>\n\n\n\n<p>Tidigare har leverant\u00f6rerna ogiltigf\u00f6rklarat garantierna, men i takt med att immersionskylning har blivit mer etablerad i datacenter&nbsp;<span id=\"urn:enhancement-19730278\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span>N\u00e4r det g\u00e4ller kylning genom neds\u00e4nkning av v\u00e4tska ogiltigf\u00f6rklarar inte l\u00e4ngre leverant\u00f6rerna garantierna.<\/p>\n\n\n\n<p>Dessutom \u00e4r m\u00e5nga l\u00f6sningar f\u00f6r kylning genom neds\u00e4nkning, som GRC, kompatibla med alla st\u00f6rre <span id=\"urn:enhancement-9571ea22\" class=\"textannotation disambiguated wl-thing\">server<\/span> leverant\u00f6r och de flesta rackupps\u00e4ttningar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vikt<\/h3>\n\n\n\n<p>Vikt har historiskt sett varit en utmaning n\u00e4r det g\u00e4ller v\u00e4tskekylning, och mer specifikt f\u00f6r rackmonterade l\u00f6sningar. <\/p>\n\n\n\n<p>Vikten kan vara ett relevant problem, men det beror mer p\u00e5 systemets densitet \u00e4n p\u00e5 v\u00e4tskans vikt.<\/p>\n\n\n\n<p>D\u00e4rut\u00f6ver, <span id=\"urn:enhancement-2ecf7354\" class=\"textannotation disambiguated wl-thing\">luftkylning<\/span> <span id=\"urn:enhancement-32c7fe52\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> \u00e4r inte l\u00e4ngre n\u00f6dv\u00e4ndigt med immersionskylning, vilket minskar totalvikten avsev\u00e4rt eftersom tunga CRAC\/chillers\/optimerare etc. ers\u00e4tts.<\/p>\n\n\n\n<p>Med de golvbelastningsm\u00f6jligheter som finns i moderna datacenter och de utrymmesbesparingar som immersionskylning inneb\u00e4r, borde vikten inte vara ett f\u00f6rebyggande problem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">S\u00e4kerhet<\/h3>\n\n\n\n<p>Vid kylning genom neds\u00e4nkning anv\u00e4nds oftast icke brandfarliga och giftfria v\u00e4tskor. Halkolyckor p\u00e5 grund av v\u00e4tskespill \u00e4r ett v\u00e4lgrundat problem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Golvutrymme<\/h3>\n\n\n\n<p>Ett av de st\u00f6rre merv\u00e4rdena med immersionskylning \u00e4r att den sparar golvyta. <\/p>\n\n\n\n<p>Immersionskylning \u00e4r utrymmeseffektivt och eliminerar behovet av alla de <span id=\"urn:enhancement-d33bdd8a\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> kr\u00e4vs f\u00f6r <span id=\"urn:enhancement-2ae00e6a\" class=\"textannotation disambiguated wl-thing\">luftkylning<\/span>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sammanfattning av resursf\u00f6rbrukning: Kylsystem<\/h3>\n\n\n\n<p>Immersionskylning f\u00f6rbrukar radikalt mindre energi och vatten \u00e4n andra kylningsalternativ. I takt med att datacenters bidrag till v\u00e4rldens resursf\u00f6rbrukning \u00f6kar blir det allt viktigare att f\u00f6rb\u00e4ttra resursf\u00f6rbrukningseffektiviteten i v\u00e5ra datacenter <span id=\"urn:enhancement-b279a701\" class=\"textannotation disambiguated wl-thing\">infrastruktur<\/span> system.<\/p>\n\n\n\n<p>Baserat p\u00e5 alla relevanta \u00f6verv\u00e4ganden har m\u00e5nga f\u00f6retag insett den potentiella \u00f6verl\u00e4gsenheten hos immersion cooling, och ett f\u00f6retag har g\u00e5tt s\u00e5 l\u00e5ngt som att&nbsp;<a rel=\"noopener noreferrer\" href=\"https:\/\/natick.research.microsoft.com\/\" target=\"_blank\">bygga ett helt datacenter under vattnet<\/a>. <\/p>\n\n\n\n<p>\u00c4ven om det kanske inte \u00e4r m\u00f6jligt f\u00f6r ditt datacenter, b\u00f6r du allvarligt \u00f6verv\u00e4ga potentialen f\u00f6r immersionskylning f\u00f6r din maskinvara.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kraft<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Distribution<\/h3>\n\n\n\n<p>Det uppskattas att en tredjedel av serverns energi g\u00e5r till spillo innan den anv\u00e4nds f\u00f6r ber\u00e4kningar.<\/p>\n\n\n\n<p>En stor del g\u00e5r f\u00f6rlorad i n\u00e4taggregatet, d\u00e4r v\u00e4xelstr\u00f6m omvandlas till likstr\u00f6m, och i sp\u00e4nningsregulatorn, d\u00e4r n\u00e4taggregatets utg\u00e5ng omvandlas till de sp\u00e4nningar som mikrochipen anv\u00e4nder. D\u00e4rf\u00f6r \u00e4r det viktigt att investera i effektiva n\u00e4taggregat och sp\u00e4nningsregulatorer.<\/p>\n\n\n\n<p>En liten f\u00f6r\u00e4ndring \u00e4r att placera reservbatterierna i sj\u00e4lva serverracken och ta bort ett omvandlingssteg fr\u00e5n AC till DC.<\/p>\n\n\n\n<p>En annan bra metod \u00e4r att placera de h\u00f6gre sp\u00e4nningarna n\u00e4rmare n\u00e4taggregatet \u00e4n de l\u00e4gre sp\u00e4nningarna, vilket minskar ledningsf\u00f6rlusterna.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Batterier: Li-ion-batterier, VRLA eller Nickel-Zink?<\/h2>\n\n\n\n<p>\u00c4ven om batterier troligen inte \u00e4r det f\u00f6rsta du t\u00e4nker p\u00e5 n\u00e4r datacenters energi kommer p\u00e5 tal, \u00e4r de en integrerad del av energin i datacenter. I det h\u00e4r avsnittet g\u00e5r vi igenom tre av de viktigaste batterialternativen.<\/p>\n\n\n\n<p>Ventilreglerade blybatterier (VRLA) har varit standard i m\u00e5nga \u00e5r, men de har vissa nackdelar j\u00e4mf\u00f6rt med andra alternativ:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VRLA \u00e4r mindre energieffektivt \u00e4n andra alternativ<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>VRLA \u00e4r mycket farligt - elektrolyten (svavelsyra) inuti \u00e4r fr\u00e4tande, medan blykomponenten bland annat kan orsaka skador p\u00e5 nervsystemet<\/li>\n\n\n\n<li>L\u00e4gre batteritid<\/li>\n\n\n\n<li>L\u00e5ngsammare att ladda<\/li>\n\n\n\n<li>F\u00e4rre urladdningscykler<\/li>\n\n\n\n<li>Ej brandfarlig<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Li-ion-batterier \u00e5 andra sidan:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Har en h\u00f6gre initialkostnad<\/li>\n\n\n\n<li>Ge b\u00e4ttre effektivitet<\/li>\n\n\n\n<li>H\u00e5ller l\u00e4ngre - ofta lika l\u00e4nge som UPS:en<\/li>\n\n\n\n<li>Mindre urladdning, snabbare laddning och fler urladdningscykler<\/li>\n\n\n\n<li>\u00c4r brandfarliga (f\u00e5r inte \u00f6verstiga 104 grader Fahrenheit)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Nickel- och zinkbatterier (fr\u00e5n ZincFive):<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Laddar snabbare \u00e4n antingen<\/li>\n\n\n\n<li>Har fler urladdningscykler \u00e4n b\u00e5de<\/li>\n\n\n\n<li>J\u00e4mf\u00f6rbar batteritid med Li-ion<\/li>\n\n\n\n<li>H\u00f6gre effektt\u00e4thet<\/li>\n\n\n\n<li>L\u00e5g v\u00e4rmeeffekt<\/li>\n\n\n\n<li>Ej brandfarlig eller giftig<\/li>\n\n\n\n<li>J\u00e4mf\u00f6rbar kostnad med avancerade blybatterier, l\u00e4gre prislapp \u00e4n h\u00f6gpresterande Li-Ion-batterier<\/li>\n<\/ul>\n\n\n\n<p>Nickel-zink-tekniken i sig \u00e4r inte ny, men den har aldrig tidigare till\u00e4mpats p\u00e5 datacenter p\u00e5 samma s\u00e4tt. Det kan visa sig vara ett s\u00e4krare och mer milj\u00f6v\u00e4nligt alternativ f\u00f6r datacenter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Virtualisering<\/h2>\n\n\n\n<p>Med servervirtualisering beh\u00f6ver ett datacenter inte lika m\u00e5nga servrar f\u00f6r att hantera sin arbetsbelastning. <\/p>\n\n\n\n<p>Med f\u00e4rre servrar kan den totala energif\u00f6rbrukningen minskas kraftigt. \u00c4ven om det ligger utanf\u00f6r ramen f\u00f6r den h\u00e4r artikeln har Gartner nyligen publicerat en&nbsp;<a rel=\"noopener noreferrer\" href=\"https:\/\/blogs.gartner.com\/michael-warrilow\/the-future-of-server-virtualization\/\" target=\"_blank\">uppdatering av virtualiseringslandskapet<\/a>. <\/p>\n\n\n\n<p>Om du k\u00f6r en f\u00f6r\u00e5ldrad version och funderar p\u00e5 att uppgradera till Windows Server 2019, l\u00e4s d\u00e5 v\u00e5r <a href=\"https:\/\/exittechnologies.com\/sv\/blogg\/datacenter\/windows-server-2019-nyckelfunktioner\/\">blogg om Windows Server 2019 Nyckelfunktioner<\/a> f\u00f6r mer information.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">AI<\/h2>\n\n\n\n<p>AI kan vara ov\u00e4rderligt i datacentret, med&nbsp;<a rel=\"noopener noreferrer\" href=\"https:\/\/deepmind.com\/blog\/deepmind-ai-reduces-google-data-centre-cooling-bill-40\/\" target=\"_blank\">Google anger en \u00f6kning av kylningseffektiviteten med 40%<\/a> efter att ha sl\u00e4ppt l\u00f6s DeepMind p\u00e5 sitt datacenter. <\/p>\n\n\n\n<p>\u00c4ven om det inte \u00e4r troligt att Google kommer att dela Deepmind som en \u00f6ppen k\u00e4llkod inom en snar framtid, erbjuder andra f\u00f6retag som Verdigris potentiella l\u00f6sningar f\u00f6r att utnyttja djupinl\u00e4rning f\u00f6r energieffektivitet i datacenter:<\/p>\n\n\n\n\n\n<p>Det \u00e4r oundvikligt att andra l\u00f6sningar kommer att dyka upp f\u00f6r att ge liknande m\u00f6jligheter i framtiden, \u00e4ven om det \u00e4r ganska torrt i poolen just nu.<\/p>\n\n\n\n<p>Det \u00e4r viktigt att notera att djupinl\u00e4rning och AI-baserade system f\u00f6r att f\u00f6rb\u00e4ttra energieffektiviteten inte \u00e4r samma sak som DCIM-verktyg (Data Center Infrastructure Management).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">DCIM<\/h2>\n\n\n\n<p>DCIM \u00e4r fundamentalt annorlunda \u00e4n AI, eftersom det fortfarande \u00e4r m\u00e4nniskan som har all kontroll. <\/p>\n\n\n\n<p>DCIM-verktyg kan anv\u00e4ndas f\u00f6r att optimera driften av datacenter, men med den enorma m\u00e4ngd data som de hanterar kan verktygen helt enkelt inte bearbeta och agera p\u00e5 insikterna som en AI kan.<\/p>\n\n\n\n<p>Med detta sagt kan energispecifika DCIM-system som&nbsp;<a rel=\"noopener noreferrer\" href=\"https:\/\/www.schneider-electric.com\/en\/work\/campaign\/ecostruxure-it\/\" target=\"_blank\">Schneider Electrics Ecostruxure IT<\/a>&nbsp;kan visa sig vara till stor hj\u00e4lp och mer l\u00e4ttillg\u00e4ngliga \u00e4n frukterna av AI:s arbete. <\/p>\n\n\n\n<p>Med \u00f6kad insyn i vad som h\u00e4nder i ditt datacenter kan du fatta mer v\u00e4lgrundade beslut; \u00e5tminstone tills programmen f\u00f6r djupinl\u00e4rning kan hantera allt \u00e5t oss.<\/p>\n\n\n\n<p>DCIM-verktyg g\u00f6r det m\u00f6jligt f\u00f6r chefer och administrat\u00f6rer att hitta dessa servrar och rensa upp d\u00e5ligt optimerade arbetsbelastningar, samt att enkelt hantera byggnads- och milj\u00f6kontroller f\u00f6r b\u00e4ttre energieffektivitet.&nbsp;<\/p>\n\n\n\n<p>F\u00f6rlita dig dock inte bara p\u00e5 verktygen: b\u00e4sta praxis f\u00f6r energieffektivitet i datacenter omfattar manuella inspektioner f\u00f6r att f\u00e5 insikter som eventuellt missas av n\u00e4tverksverktyg.<\/p>\n\n\n\n<p>While optimizing your PUE is essential, the most effective way to eliminate energy waste from &#8220;zombie servers&#8221; is to utilize professional <a href=\"https:\/\/exittechnologies.com\/sv\/datacentertjanster\/data-center-decommissioning-services\/\">tj\u00e4nster f\u00f6r avveckling av datacenter<\/a> to safely remove and monetize inefficient legacy hardware.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Slutsatser: F\u00f6rb\u00e4ttrad effektivitet och kostnadsbesparingar<\/h2>\n\n\n\n<p>Genom att anv\u00e4nda tekniken, strategin och teknologin i denna guide f\u00f6r <a href=\"https:\/\/exittechnologies.com\/sv\/blogg\/it-tips\/strategi-for-konsolidering-av-datacenter-en-omfattande-guide\/\"><strong>b\u00e4sta praxis f\u00f6r energieffektivitet i datacenter<\/strong><\/a>kan du stadigt n\u00e4rma dig det perfekta PUE-indexet p\u00e5 1,0 som f\u00f6retag som Google och Facebook har, och d\u00e4rmed dra nytta av de driftskostnadsbesparingar och den l\u00e4gre milj\u00f6p\u00e5verkan som f\u00f6ljer med ett effektivare datacenter. <\/p>\n\n\n\n<p>\u00c4ven om det finns mycket h\u00e4r finns det ingen anledning att ta itu med allt p\u00e5 en g\u00e5ng.<\/p>\n\n\n\n<p><strong>Vet du om att din kylning inte uppfyller branschstandarderna?<\/strong> Kanske kan du kontakta leverant\u00f6rer av l\u00f6sningar f\u00f6r att f\u00f6rb\u00e4ttra det omr\u00e5det.<\/p>\n\n\n\n<p><strong>Saknar du verklig insyn som hj\u00e4lper dig att hantera ditt datacenter p\u00e5 ett effektivt s\u00e4tt?<\/strong> B\u00f6rja med att utv\u00e4rdera marknaden f\u00f6r DCIM-verktyg f\u00f6r att hj\u00e4lpa dig att fatta v\u00e4lgrundade beslut.<\/p>\n\n\n\n<p><strong>Beh\u00f6ver du frig\u00f6ra golvyta och har \u00e5ldrande servrar?<\/strong> Unders\u00f6k alternativen f\u00f6r servervirtualisering tillsammans med teamet. Oavsett omr\u00e5de kommer det n\u00e4stan alltid att l\u00f6na sig att g\u00e5 vidare med konsekventa insatser f\u00f6r omr\u00e5den som sl\u00e4par efter i form av f\u00f6rb\u00e4ttringar av OPEX eller milj\u00f6p\u00e5verkan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vi r\u00f6r oss fram\u00e5t: Allt m\u00e5ste beaktas f\u00f6r framtidss\u00e4kring av nya datacenter<\/h2>\n\n\n\n<p>Eftersom datacenter f\u00f6rbrukar allt mer energi m\u00e5ste vi vara medvetna om v\u00e5r p\u00e5verkan p\u00e5 infrastrukturen, v\u00e5ra energisystem och v\u00e4rlden. <\/p>\n\n\n\n<p>Att uppgradera befintliga datacenter kan bara vara meningsfullt i begr\u00e4nsad kapacitet, eftersom m\u00e5nga l\u00f6sningar inte \u00e4r kostnadseffektiva eller v\u00e4rda anstr\u00e4ngningen f\u00f6r befintliga anl\u00e4ggningar.<\/p>\n\n\n\n<p>Dessa metoder \u00e4r s\u00e4rskilt viktiga efter&nbsp;<a href=\"https:\/\/exittechnologies.com\/sv\/datacentertjanster\/likvidation\/\"><span id=\"urn:local-annotation-706101\" class=\"textannotation disambiguated wl-link\">avveckling av befintliga datacenter<\/span><\/a> och bygga ut de nya. <\/p>\n\n\n\n<p>Om du funderar p\u00e5 vilken typ av servrar du ska skaffa till ett nytt datacenter, se till att l\u00e4sa v\u00e5ra inl\u00e4gg om <a href=\"https:\/\/exittechnologies.com\/sv\/blogg\/datacenter\/serveruppgradering-inkop-white-box-servrar\/\">servrar i vit box<\/a> och <a href=\"https:\/\/exittechnologies.com\/sv\/blogg\/datacenter\/hpe-vs-dell-servrar\/\">j\u00e4mf\u00f6ra servrar fr\u00e5n HPE och Dell<\/a> f\u00f6r att hitta det som passar b\u00e4st f\u00f6r dina behov.<\/p>\n\n\n\n<p>Mer energieffektiva datacenter kommer att bidra till att g\u00f6ra dem mer kostnadseffektiva, b\u00e5de f\u00f6r datacenteroperat\u00f6rer och slutanv\u00e4ndare, och till att g\u00f6ra varje enskilt datacenter mer milj\u00f6v\u00e4nligt. I takt med att efterfr\u00e5gan p\u00e5 datacenterkapacitet forts\u00e4tter att \u00f6ka kommer det att bli allt viktigare att ha effektivare system p\u00e5 plats f\u00f6r att balansera deras energibehov och h\u00e5lla kostnaderna nere f\u00f6r alla.<\/p>\n\n\n\n<p>S\u00e5 l\u00e4nge vi verkligen anstr\u00e4nger oss f\u00f6r att f\u00f6rb\u00e4ttra v\u00e5r energieffektivitet kan vi h\u00e5lla v\u00e5r milj\u00f6p\u00e5verkan p\u00e5 en minimal niv\u00e5 och njuta av den stora bl\u00e5 kulan p\u00e5 himlen som vi kallar v\u00e5rt hem i m\u00e5nga \u00e5r fram\u00f6ver.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 10<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>This Data Center Energy Efficiency Best Practices Guide was made to help data centers curb their primary operational cost: energy consumption. As data consumption continues its exponential growth, data centers will need to maximize their energy efficiency to avoid being crippled by power costs. This article will cover the best practices that data centers can [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":70198,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"episode_type":"","audio_file":"","podmotor_file_id":"","podmotor_episode_id":"","cover_image":"","cover_image_id":"","duration":"","filesize":"","filesize_raw":"","date_recorded":"","explicit":"","block":"","itunes_episode_number":"","itunes_title":"","itunes_season_number":"","itunes_episode_type":"","footnotes":""},"categories":[43],"tags":[],"class_list":["post-70193","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-center"],"acf":[],"_links":{"self":[{"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/posts\/70193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/comments?post=70193"}],"version-history":[{"count":0,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/posts\/70193\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/media\/70198"}],"wp:attachment":[{"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/media?parent=70193"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/categories?post=70193"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exittechnologies.com\/sv\/wp-json\/wp\/v2\/tags?post=70193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}