{"id":78481,"date":"2026-10-13T11:00:00","date_gmt":"2026-10-13T11:00:00","guid":{"rendered":"https:\/\/exittechnologies.com\/?p=78481"},"modified":"2026-11-19T03:13:46","modified_gmt":"2026-11-19T03:13:46","slug":"guide-to-liquid-cooling-decommissioning-and-retirement","status":"publish","type":"post","link":"https:\/\/exittechnologies.com\/nl\/blog\/gpu\/guide-to-liquid-cooling-decommissioning-and-retirement\/","title":{"rendered":"Decommissioning Liquid-Cooled AI Racks: How to Drain, Dispose and Document"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 7<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"78481\" class=\"elementor elementor-78481\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3879b0ca e-flex e-con-boxed e-con e-parent\" data-id=\"3879b0ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6bf6cad elementor-widget elementor-widget-text-editor\" data-id=\"6bf6cad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Most GPU decommissioning playbooks were written for gear you unplug and roll out. What happens when they\u2019re high-density direct-to-chip (D2C) racks?<\/p>\n<p>A liquid-cooled rack adds a drain sequence, a fluid you must identify before you can legally dispose of it, and paperwork that belongs next to your certificates of destruction. Miss any of it in planning and you pay on site in schedule slips, spills, or a compliance gap you didn&#8217;t know you had.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<h2><strong>\u00a0<\/strong><\/h2>\n<h2><strong>Fast Facts: What You Need To Know About Decommissioning Liquid Cooled IT Gear<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:list --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul><!-- wp:list-item --><\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>\n<p data-lfile-container=\"2332ee5f-89f1-4e5e-b2ec-99cc388b8a4e\" data-pm-slice=\"1 1 [&quot;table&quot;,{&quot;bid&quot;:&quot;m8sb791aqz4.862&quot;,&quot;suggestId&quot;:null,&quot;suggestOp&quot;:null,&quot;suggestSet&quot;:null,&quot;suggestWas&quot;:null,&quot;suggestFrom&quot;:null},&quot;tableRow&quot;,{&quot;bid&quot;:&quot;m8sb791aqz4.1156&quot;,&quot;suggestId&quot;:null,&quot;suggestOp&quot;:null,&quot;suggestSet&quot;:null,&quot;suggestWas&quot;:null,&quot;suggestFrom&quot;:null},&quot;cell&quot;,{&quot;bid&quot;:&quot;m8sb791aqz4.1237&quot;,&quot;suggestId&quot;:null,&quot;suggestOp&quot;:null,&quot;suggestSet&quot;:null,&quot;suggestWas&quot;:null,&quot;suggestFrom&quot;:null,&quot;header&quot;:false,&quot;colspan&quot;:1,&quot;rowspan&quot;:1,&quot;colwidth&quot;:null,&quot;align&quot;:null,&quot;background&quot;:null}]\">Liquid cooling is expected to reach about 53% of high-end AI infrastructure in 2026, up from roughly 33% in 2025 (<a href=\"https:\/\/www.trendforce.com\/presscenter\/news\/20260817-13183.html\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TrendForce<\/a>).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><!-- wp:list-item --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>The cooling loop must be isolated and drained before de-racking starts, and OCP guidance uses compressed dry air below 75 psi to push residual fluid under 5%.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><!-- wp:list-item --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Most direct-to-chip loops run PG25 (75% water, 25% propylene glycol), which contains no PFAS itself. Check the SDS for additives.\u00a0<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><!-- wp:list-item --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Immersion systems use dielectric fluids that can contain PFAS and follow a different disposal path.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><!-- wp:list-item --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Drain logs, waste determinations, and disposal records belong in the same chain-of-custody file as your data destruction records.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><!-- wp:list-item --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>A GPU tray that&#8217;s drained, dried and documented keeps its resale value. A half-drained one invites corrosion, which cuts into that value.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><\/p>\n<p><!-- \/wp:list --><!-- wp:heading --><\/p>\n<h2><strong>\u00a0<\/strong><\/h2>\n<h2><strong>Why Liquid-Cooled Racks Are Reaching Retirement Now<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p><a href=\"https:\/\/www.trendforce.com\/presscenter\/news\/20260817-13183.html\" target=\"_blank\" rel=\"noreferrer noopener\">TrendForce projects<\/a> liquid cooling in high-end AI infrastructure will climb from about 33% in 2025 to 53% in 2026.\u00a0<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Heat density forced the change. HPE lists a nominal 132 kW per GB200 NVL72 rack, with peak draw around 192 kW compared with 8-12 kW for a typical air-cooled rack.\u00a0<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Those figures track what&#8217;s going into data halls. With IT equipment commonly refreshed every three to five years, that puts the first big wave of liquid-cooled racks on decommission schedules right now.\u00a0<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<h2><strong>\u00a0<\/strong><\/h2>\n<h2><strong>Decommissioning A Liquid-Cooled GPU Rack Starts With Plumbing<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>On an air-cooled rack, removal starts once power is off and cables are labeled. On a liquid-cooled rack, removal waits on the technology cooling system (TCS), which is the loop running from the coolant distribution unit (CDU) through the rack manifold to every cold plate. Technicians need to isolate that system from facility water and drain it.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>The steps to perform a drain procedure are well documented. <a href=\"https:\/\/www.opencompute.org\/documents\/considerations-for-shipping-and-storage-of-1-phase-coldplate-liquid-cooled-racks-and-servers-final-march-2026-pdf\/\" target=\"_blank\" rel=\"noopener\">The Open Compute Project&#8217;s March 2026 guidance<\/a> on shipping and storing cold plate hardware, written by engineers from Meta and NVIDIA, describes purging assemblies with compressed clean dry air below 75 psi for several minutes to bring residual fluid under 5%. It defines &#8220;dry&#8221; hardware as under 10% coolant by volume and says to release purge pressure before transport.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Weight is the second change. A fully loaded GB200 NVL72 rack at about 3,245 pounds, per <a href=\"https:\/\/www.hpe.com\/us\/en\/collaterals\/collateral.a50009224enw.html\" target=\"_blank\" rel=\"noopener\">HPE&#8217;s spec sheet<\/a>, calls for rated lift equipment and a floor-loading check along the entire exit path, from the rack position to the dock.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Operators close and tag the valves on the facility side, then the rack side gets drained and purged. Only then does anyone break a connection or pull a tray.\u00a0<\/p>\n<h3>\u00a0<\/h3>\n<h3><b>Who Owns What in a Colocation Facility<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">In colocation, most delays come from one unanswered question: who drains what? Settle it in writing before the project starts. A typical split looks like this:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Facility water loop and chillers:<\/b><span style=\"font-weight: 400;\"> owned by the colocation provider and left running.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Coolant distribution unit (CDU):<\/b><span style=\"font-weight: 400;\"> usually the provider\u2019s. In-rack CDUs are often the tenant\u2019s. Whoever owns it isolates it.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Row manifold or technology cooling system:<\/b><span style=\"font-weight: 400;\"> varies the most. Agree in writing who isolates and drains it.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Rack manifold, hoses, quick-disconnects and cold plates:<\/b><span style=\"font-weight: 400;\"> the tenant\u2019s, drained by the tenant or its decommissioning partner.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Coolant in the tenant-side loop:<\/b><span style=\"font-weight: 400;\"> usually the tenant&#8217;s. Agree in writing who the waste generator is and who signs the waste determination.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Contracts vary, so treat this as a starting point and confirm against your colocation agreement.<\/span><\/p>\n<h3>\u00a0<\/h3>\n<h3><b>Drain-and-cap sequence for a cold plate rack<\/b><\/h3>\n<p>\u00a0<\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Confirm the coolant and volumes. Pull the SDS, estimate loop volume, and book the waste hauler or glycol recycler before the drain date.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Agree on the ownership boundary in writing<\/span><span style=\"font-weight: 400;\"> (see \u201cWho Owns What in a Colocation Facility\u201d above)<\/span><span style=\"font-weight: 400;\">, including who signs the waste determination.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Power down the IT load and let the loop return to room temperature.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Close, lock out and tag the isolation valves at the CDU or row manifold. Photograph the tags.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Drain the rack-side loop into labeled, closed containers. Keep drip trays and absorbent pads under every quick-disconnect, and leave leak detection on.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Purge with clean dry air below 75 psi for several minutes, until residual coolant is under about 5% (<\/span><a href=\"https:\/\/www.opencompute.org\/documents\/considerations-for-shipping-and-storage-of-1-phase-coldplate-liquid-cooled-racks-and-servers-final-march-2026-pdf\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">OCP, March 2026<\/span><\/a><span style=\"font-weight: 400;\">).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disconnect and cap every port.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Choose the final state: ship dry (under 10% coolant by volume), or charge with nitrogen at 25\u201350 psi for storage, which typically holds for 3\u201312 months. Avoid partly drained storage, which invites corrosion.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check the lift and floor path. A fully loaded GB200 NVL72 rack weighs about 3,245 lb.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Log it all in the rack\u2019s audit file (checklist below) before the rack leaves the floor.<\/span><\/li>\n<\/ol>\n<p>This is a general outline. Always follow the equipment manufacturer&#8217;s procedures and your site&#8217;s safety requirements.<\/p>\n<h2>\u00a0<\/h2>\n<h2><strong>Your Disposal Path Depends On Which Fluid You\u2019re Using<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Single-phase direct-to-chip cooling holds about 55% of the liquid cooling market in 2026, according to Schneider Electric, and it typically runs PG25. At a 25% concentration, propylene glycol makes the mix biostatic, which slows bacterial growth on cold plate fins spaced around 50 microns apart. It is also far less toxic than ethylene glycol, which is why OCP recommends it.<\/p>\n<h5 dir=\"ltr\"><strong>Coolant Disposal Paths:<\/strong><\/h5>\n<p dir=\"ltr\">The coolant in the loop decides the disposal path. The three you\u2019re most likely to find:<\/p>\n<p dir=\"ltr\"><strong>PG25 (25% propylene glycol, 75% water).<\/strong> The standard coolant in single-phase direct-to-chip systems. Propylene glycol and water are not PFAS, but check the SDS for the inhibitor package. Send it to a glycol recycler or licensed waste hauler, and don\u2019t pour it down a drain unless your local wastewater authority allows it. Keep the drain log, the waste determination, and the shipping paperwork or recycling receipt.<\/p>\n<p dir=\"ltr\"><strong>Hydrocarbon dielectric fluids (synthetic or mineral oils).<\/strong> Common in single-phase immersion. They\u2019re generally PFAS-free, but confirm on the SDS. Depending on condition, they can often be filtered and reused, or sent to a recycler that accepts them. Keep the SDS, the volume recovered, and the reclaim or recycling receipt.<\/p>\n<p dir=\"ltr\"><strong>Fluorinated dielectric fluids (fluorocarbons).<\/strong> Used in two-phase immersion and some single-phase systems. Many are classed as PFAS. They evaporate easily, so keep containers sealed. Send them to a specialist reclaimer, or back through the fluid supplier if it offers a take-back program. Keep the SDS, the volume recovered, the chain of custody to the reclaimer, and a note of whether any state PFAS rules apply.<\/p>\n<p dir=\"ltr\">This is general guidance. Your environmental, health and safety (EHS) team and the fluid\u2019s SDS decide the final path.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Immersion systems come with different considerations. Immersion tanks use dielectric fluids, and two-phase systems have historically relied on fluorocarbon fluids containing PFAS, including 3M&#8217;s Novec line. 3M announced in 2022 that it would exit PFAS manufacturing by the end of 2025. EPA&#8217;s TSCA section 8(a)(7) PFAS reporting period now opens no later than January 31, 2027, after several postponements <a href=\"https:\/\/www.ul.com\/news\/epa-delays-tsca-section-8a7-pfas-reporting-start-date\" target=\"_blank\" rel=\"noopener\">(UL Summary)<\/a> and several states have their own PFAS reporting rules so check yours.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Identify the fluid from the safety data sheet and system documentation before the drain date. PG25 from a cold plate loop and a fluorocarbon from a two-phase tank leave your building on completely different paperwork.\u00a0<\/p>\n<p>Immersion retirement works differently, and it depends on the type of tank. In single-phase immersion, which uses oils that don\u2019t evaporate, servers are lifted out and left to drip over the tank. Oil works its way into slots, connectors and under labels, so a wipe-down usually isn\u2019t enough for resale. Plan for a more thorough cleaning step, such as a dielectric solvent wash. In two-phase immersion, the fluid evaporates quickly once hardware leaves the tank, so the hardware comes out nearly dry and the focus shifts to keeping fluid loss to a minimum. Either way, immersion fluids are expensive, so recovered fluid can often be filtered and reused rather than discarded. Buyers inspect immersion-run hardware more closely, so keep cleaning records in the audit file.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<h2><strong>\u00a0<\/strong><\/h2>\n<h2><strong>GPU Rack Coolant Disposal Needs Its Own Chain of Custody<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Quick-disconnect fittings still leak a little. Schneider&#8217;s thermal engineers <a href=\"https:\/\/blog.se.com\/datacenter\/2026\/08\/14\/what-coolant-for-data-center-liquid-cooling-pg25-dielectric-fluids-ashrae-recommendations\/\" target=\"_blank\" rel=\"noreferrer noopener\">note<\/a> that QDs often give a slightly wetted disconnect instead of a fully dry break, which is part of why the industry settled on low-toxicity PG25. Across a row of racks those drops add up, so keep drip trays, absorbent pads, and leak detection active until the last hose comes off.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Used coolant is not automatically hazardous waste. <a href=\"https:\/\/rcrapublic.epa.gov\/files\/14163.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">The EPA&#8217;s position<\/a> is that glycol coolant isn&#8217;t a listed hazardous waste, so it only has to be managed as one if it shows a hazardous characteristic, typically confirmed with a Toxicity Characteristic Leaching Procedure (TCLP) test. Whoever drains it has to make and document that determination, states can regulate it more strictly, and pouring it down a floor drain isn&#8217;t an option without approval from the local wastewater authority.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><span style=\"font-weight: 400;\">Coolant disposal is governed by RCRA and your state environmental agency, so ask any decommissioning vendor how they handle it and who hauls it.<\/span><\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Your audit file needs the same rigor you already demand for drives, keep one per rack:<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul><!-- wp:list-item --><\/ul>\n<\/li>\n<\/ul>\n<h3><b>Close-Out Audit File: One per Rack<\/b><\/h3>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Rack ID, asset tags and serial numbers of all trays<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Coolant SDS and coolant type<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Photos of tagged isolation valves before the drain<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Drain log: date, technician, volume recovered<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Purge record: pressure, duration, residual check<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Final state: dry, or nitrogen-charged (pressure and date)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Waste determination (TCLP results or generator knowledge, signed)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Hauler manifest or recycling receipt for the coolant<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Freight bill of lading and temperature mode<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Data sanitization certificates for every drive<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Final disposition per serial: redeployed, resold, harvested or recycled<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><\/p>\n<p><!-- \/wp:list --><!-- wp:heading --><\/p>\n<h2><strong>\u00a0<\/strong><\/h2>\n<h2><strong>Plan Your Cooling Exit Strategy In Advance<\/strong><\/h2>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Drain-and-cap work belongs in the project plan on day one, next to asset inventory and data sanitization, because it controls crew skills, lift rentals, freight mode, and the order racks leave the floor. <a href=\"https:\/\/exittechnologies.com\/data-center-services\/data-center-decommissioning-services\/\">A full decommissioning project plan<\/a> should name who isolates facility water, who drains the rack side, which fluid sits in each loop, and where every drum goes.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Freight requires its own line item. OCP&#8217;s guidance puts standard road freight between -20\u00b0C and 45\u00b0C; a<span style=\"font-weight: 400;\">ny PG25 left in the hardware can thicken or freeze in cold weather, so winter shipments may need temperature-controlled freight.<\/span><\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Liquid cooling changes how the hardware comes out of the rack. A retired GPU&#8217;s value still comes down to model, condition, test results, and what the secondary market is paying at the time. <span style=\"font-weight: 400;\">The exception is a tray that was partly drained or stored wet. Residual coolant can corrode cold plates and connectors, and corrosion is exactly the kind of condition issue that lowers what a buyer will pay.<\/span><\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>The one place a coolant loop can still cost you money is the warehouse. OCP flags hardware left partially drained as a high corrosion risk that isn&#8217;t suited to long-term storage, while fully dried assemblies charged with nitrogen at 25 to 50 psi typically hold for 3 to 12 months. Once your trays are dry and documented, <a href=\"https:\/\/exittechnologies.com\/sell\/graphics-card\/\">see what your retired GPUs are worth<\/a>.<\/p>\n<p><span style=\"font-weight: 400;\">Draining adds steps to retirement, but the goal hasn\u2019t changed. Racks that leave dry and documented keep their resale and redeployment value, stay out of the waste stream longer, and give sustainability and audit teams records they can rely on. Plan the drain the day you plan the refresh, not the week before the trucks arrive.<\/span><\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 7<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>Most GPU decommissioning playbooks were written for gear you unplug and roll out. What happens when they\u2019re high-density direct-to-chip (D2C) racks? A liquid-cooled rack adds a drain sequence, a fluid you must identify before you can legally dispose of it, and paperwork that belongs next to your certificates of destruction. Miss any of it in [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":78490,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[104],"tags":[],"class_list":["post-78481","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gpu"],"acf":[],"_links":{"self":[{"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/posts\/78481","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/comments?post=78481"}],"version-history":[{"count":22,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/posts\/78481\/revisions"}],"predecessor-version":[{"id":78847,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/posts\/78481\/revisions\/78847"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/media\/78490"}],"wp:attachment":[{"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/media?parent=78481"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/categories?post=78481"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exittechnologies.com\/nl\/wp-json\/wp\/v2\/tags?post=78481"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}